Top

Tomey MR-6000 System 6 in 1 Multifunction Unit

Original price was: $17,999.00.Current price is: $13,999.00.

The Tomey MR-6000 System, 6 in 1 Multifunction Unit, is a comprehensive and versatile diagnostic tool for various ophthalmic examinations. With its six diagnostic functions, advanced features, and user-friendly interface, the MR-6000 offers an all-in-one solution for eye care professionals seeking precise and accurate results.

In stock

- +

Description

Tomey MR-6000 performs  Refraction, Keratometry, Topography, Tonometry, Pachymetry, and Dry Eye Analysis exams with meibomian glands, tear film, and conjunctiva fully automatically, with the simple touch of a button.

MR-6000 favors diversified care, from basic to complex, and facilitates the accuracy of diagnoses in uncooperative patients, with nystagmus or children, in addition to optimizing the professional’s time and increasing their workflow.

It is perfect for professionals who value exams’ quality, convenience, and agility.

Tomey MR-6000 Features:

  • Simple handling: automatic alignment
  • Small footprint: 6 measurements for one single device
  • Speed: less than 3 seconds to change mode
  • High precision: the combination of different measures for precise results (automatic correction of the IOP according to the pachymetry)
  • Combined air blast and pachymetry for better interpretation of results
  • Change of Refraction / Tonometry mode in 3 seconds
  • More precise refraction thanks to LED technology: increased precision for strong ametropia, perfect focus whatever the ametropia
  • Easy measurements in children thanks to AUTO FOCUS / AUTO TRACKING mode

Efficiency, time-saving, space-saving, and reduced cost

Efficiency-time-saving-space-saving-and-reduced-cost

Fully automated, the Tomey MR-6000 integrates the powerful Eye-tracker, which already equips all the instruments in the range.

Small in size, it can be installed in the secretariat, preliminary examination room, or consultation unit. Already compatible with all business software, it integrates into the refraction chain, whatever it is brand.

Among the specificities is a QUICK REF mode for simple measurement in children or uncooperative patients. The new Air-Cut function reduces the volume of air used for taking tonometry by two.

The integration of topography and the analysis of dry eye parameters make it a complete instrument of excellent efficiency in daily use.

Refraction mode and keratometry

Refraction-mode-and-keratometry

SLD technology offers excellent measurement quality, whatever the level of opacity of the media and the level of ametropia.

Tonometry mode

The new AIR-CUT technology reduces the volume of air sent by half compared to older-generation tonometers. The intensity of the air jet is adjusted according to 3 levels according to the first measurement.

Quick Ref mode: exclusive to Tomey

Quick-Ref-mode-exclusive-to-Tomey

They allow easy measurements under challenging patients.

QUICK REF mode offers an alternative in less cooperative patients such as children and patients with nystagmus or AMD. The measurement is displayed in real-time.

Pachymetry mode

Based on the same measurement principle as the Tomey EM-4000 specular microscope, the pachymetry measurement is made by the difference in travel time between the two surfaces (epithelium and endothelium). The MR-6000 provides pachymetry-corrected tonometry values.

Topography Mode

Topography-Mode

Topography measurement has never been easier and faster thanks to the quality of the Tomey Eye-tracker. Once the measurement is made, the topographies are exported to the patient file and stored in the MR-6000’s integrated database for later comparison.

Cards available: axial or instantaneous

Many scales:
• Absolute
• Normalized
• Klyce/Wilson
• Maguire/Waring
• American style

Fourier analysis with an index of corneal regularity and asymmetry to aid in screening for keratoconus.

Dry eye analysis

Dry-eye-analysis

In addition to the traditional refraction, keratometry, pachymetry, and tonometry functions, the MR-6000 offers a wide range of tools for dry eye analysis.

Blink analysis:
The blink analysis tool consists of recording a 10-second video sequence. The ultra-high-speed camera makes it possible to measure the frequency of the blink and the palpebral opening and to check that it is complete.

Measurement of the tear prism:
The measurement of the tear prism is an essential element in dry eyes. A tear prism less than 0.2 mm suggests an increased risk of dry eye.

IR Meibography and Hyperemia.

Advantages

  • Easy operating: Auto alignment and familiar user interface
  • Space-saving: Five systems in one device
  • Time-saving: Change between the different modes in just 3 seconds
  • High accuracy: Combined data of other measurements for precise results (e.g., Tono + Pachy)
  • Improved features: friendly air puff control and enhanced refraction function
  • Complete dry eye analysis: Combination of 6 different measurements of blinking, tear film, Meibomian glands, and conjunctiva

With the Tomey MR-6000, you can minimize exam time to 90 seconds for refraction, keratometry, tonometry, pachymetry, and topography.

Get accurate refract and keratometry measurements thanks to an advanced measuring principle. The fast refractometry mode allows you to obtain refractive measurement values ​​within a few seconds, despite the loss of fixation, for example, in patients with nystagmus, children, or non-contact patients.

The new airflow technology creates a soft and barely perceptible air push. Automatic IOP correction takes into account pachymetry values ​​to obtain reliable IOP values. Diagnosis is carried out using 16 test rings in a section with a diameter of 8 mm. Several types of maps, including Fourier analysis, provide a wide range of possibilities for displaying the shape of the cornea.

A combination of 4 studies gives a detailed picture of the patient’s ocular surface state. Monitor blink rate, tear meniscus height, hyperemia, and meibomian glands using only one medical device.

Specifications:

REFRACTIVE POWER MEASUREMENT

  • Spherical power -30.00 D to +25.00 D (in VD = 12.00 mm)
  • Cylindrical power 0.00 D to ± 12.50 D (in VD = 12.00 mm)
  • Astigmatic axis 0° to 180°

KERATOMETRIC MEASUREMENT

  • Corneal curvature radius 5.00 mm to 13.00 mm
  • Corneal astigmatic axis 0° to 180°

MEASUREMENT OF INTRAOCULAR PRESSURE

  • Measuring range 1 mm Hg to 60 mm Hg (1 hPa to 80 hPa)

PACHYMETRY MEASUREMENT

  • Measuring range 300 µm to 800 µm

TOPOGRAPHY MEASUREMENT

  • Corneal curvature radius 5.50 mm to 10.00 mm
  • Corneal astigmatic axis 0° to 180°

AUXILIARY FUNCTION

  • Interpupillary distance 20 mm to 85 mm
  • Corneal diameter and pupil diameter 1.00 mm to 14.00 mm
  • Dry Eye Analysis: Blink frequency, tear meniscus height, hyperemia, Meibomian glands

DATA MANAGEMENT

  • built-in SD card
  • Integrated thermal printer
  • Data Output Type 3x USB 2.0, 1x Ethernet, 1x SD card slot
  • Export format DCM, XML, CSV, JPG, PDF

ELECTRICAL DIMENSIONS AND REQUIREMENTS

  • Dimensions 312 x 491 x 450 mm (WxLxH)
  • Weight approx. 23 kg
  • Voltage 100 VAC to 240 VAC
  • Frequency 50/60 Hz
  • Power consumption 110 VA

Small in size, it can be installed in the secretariat, preliminary examination room, or consultation unit. Already compatible with all business software, it integrates into the refraction chain, whatever it is brand. Among the specificities is a QUICK REF mode for simple measurement in children or uncooperative patients.

The new Air-Cut function halves the volume of air used for taking tonometry. The integration of topography and the analysis of dry eye parameters make it a complete instrument of excellent efficiency in daily use.

Delivery included

  • One power cord
  • One user manual
  • One printer paper
  • Two pins for chin rest paper
  • 1 Chin Rest Paper
  • 1 model eye
  • 3 Printer paper
  • 1 CL holder
  • Two spare fuses
  • One dust cover

In conclusion, the Tomey MR-6000 System 6 in 1 Multifunction Unit is a highly versatile and comprehensive diagnostic tool for various ophthalmic examinations. With six diagnostic functions, including autorefraction, keratometry, pupillometry, tonometry, pachymetry, and retro illumination, this instrument offers an all-in-one solution for eye care professionals. Its advanced features, such as the exact measurement system and user-friendly interface, make it easy to use and provide accurate results.

The compact design and portability of the Tomey MR-6000 make it ideal for use in various settings, including hospitals, clinics, and mobile practices. Overall, the Tomey MR-6000 System 6 in-1 Multifunction Unit is an excellent investment for eye care professionals seeking a comprehensive and versatile diagnostic tool to offer their patients the best possible care.

Source

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

You don't have permission to register

Reset Password