Description
The ZEISS IOLMaster 700 with SWEPT Source Biometry® builds upon almost 20 years of experience in optical biometry. Its latest update features Total Keratometry (TK®) – a unique way to implement posterior corneal surface measurement into IOL power calculation. Once again, the ZEISS IOLMaster 700 demonstrates its technological leadership. Defining next-generation biometry from ZEISS.
IOLMaster® 700 from ZEISS is the leading SWEPT Source OCT biometer, enabling you to start your workflow with more insights, experience fewer refractive surprises, and optimize your workflow.
ZEISS IOLMaster 700 Key Features:
- Total Keratometry (TK) for Comprehensive Corneal Data: The IOL Master 700 incorporates Total Keratometry, providing a comprehensive analysis of the cornea. This advanced technology ensures precise measurement of both the anterior and posterior corneal surfaces, allowing surgeons to make informed decisions based on a more complete picture.
- Swept-Source Biometry for Enhanced Accuracy: Benefit from the latest in swept-source technology, enabling the IOL Master 700 to deliver highly accurate axial length measurements even in challenging cases. This ensures accurate IOL power calculations, thereby improving refractive outcomes.
- Full Eye-Length Measurement: Obtain a comprehensive assessment of the entire eye with the IOL Master 700. From anterior chamber depth to axial length, this device covers all crucial parameters, empowering surgeons with the information needed for personalized treatment plans.
- Effortless Workflow Integration: Designed with the modern surgical environment in mind, the IOL Master 700 seamlessly integrates into your workflow. Its user-friendly interface and automated measurement processes enhance efficiency, allowing you to focus on what matters most – delivering exceptional patient care.
- Precise Toric IOL Calculations: Achieve optimal astigmatism correction with the IOL Master 700’s advanced toric IOL calculation capabilities. Accurate alignment of toric lenses is crucial for successful outcomes, and this device ensures precision at every step.
- Enhanced Connectivity and Data Management: The IOL Master 700 is equipped with advanced connectivity features that enable seamless integration with electronic medical record (EMR) systems. Efficient data management ensures easy access to patient information and facilitates collaboration among healthcare professionals.
- Trusted Zeiss Quality: As a Zeiss product, a pioneer in optical and optoelectronic technologies, the IOL Master 700 upholds the highest standards of quality and reliability. Trust in a legacy of precision and innovation to elevate your cataract surgery practice.
Detect unusual eye geometries and visually verify your measurements
The patented Cornea-to-Retina Scan allows you to detect unusual eye geometries, such as tilt or decentration of the crystalline lens. Additionally, the complex interpretation of A-scans is no longer necessary.

Optimize your cataract workflow
Streamline your refractive cataract workflow: from biometry and IOL calculations or ordering to surgical planning. Access your IOLMaster data anytime, anywhere. Enjoy exceptional speed and an outstanding cataract penetration rate, and benefit from the unique Fixation Check.

ZEISS VERACITY Surgery Planner
Connect your ZEISS IOLMaster 700 with ZEISS VERACITY Surgery Planner to streamline your cataract workflow through the cloud. IOLMaster 700 from ZEISS provides this planning solution with biometry measurements and three imaging reports: an OCT scan to screen for pathology and anatomical anomalies, a reference image for intraoperative guidance with ZEISS CALLISTO eye, and a SWEPT-source OCT analysis of the posterior cornea for Total Keratometry (TK) corneal astigmatism measurements. ZEISS VERACITY Surgery Planner also incorporates topography maps and keratometry data, such as axial length, anterior chamber depth, lens thickness, white-to-white, and more.
- Maximize efficiency by saving time
- Reduce manual entry
- Access your data from anywhere
- Integration with EMRs and diagnostics
|
Measurement range
|
Axial length
|
14 – 38 mm
|
|---|---|---|
|
Corneal radii
|
5 – 11 mm
|
|
|
Anterior chamber depth
|
0.7 – 8 mm
|
|
|
Lens thickness
|
1 – 10 mm (phakic eye)
|
|
|
0.13 – 2.5 mm (pseudophakic eye)
|
||
|
Central corneal thickness
|
0.2 – 1.2 mm
|
|
|
White-to-white
|
8 – 16 mm
|
|
|
SD of repeatability
|
Axial length
|
5 μm
|
|
Corneal radii
|
0.09 D
|
|
|
Cylinder
|
> 0.75 D, axis 3.8°
|
|
|
Anterior chamber depth
|
7 μm
|
|
|
Lens thickness
|
6 µm
|
|
|
Central corneal thickness
|
2.5 µm
|
|
|
White-to-white
|
111 µm
|
|
|
IOL calculation formulas
|
Barrett Suite: Barrett Universal II & Barrett TK Universal II*, Barrett toric & Barrett TK toric*, Barrett True K & Barrett True K with TK
|
|
|
Haigis Suite: Haigis, Haigis-L, Haigis-T
|
||
|
Hoffer® Q |
||
|
Holladay 1 and 2
|
||
|
SRK®/T |
||
|
Interfaces
|
ZEISS EQ Workplace
|
|
|
ZEISS VERACITY Surgery Planner |
||
|
ZEISS EQ Mobile
|
||
|
ZEISS FORUM eye care data management system
|
||
|
ZEISS computer-assisted cataract surgery system CALLISTO eye (via USB & FORUM)
|
||
|
Data interface for electronic medical record (EMR) / patient management systems (PMS), Holladay IOL
|
||
|
Consultant software and PhacoOptics® |
||
|
Data export to USB storage media
|
||
|
Ethernet port for network connection and network printer
|
||
* Only available with Total Keratometry license
Include:
- ZEISS IOLMaster 700
- Touch screen monitor
- Printer and Accessories
- Keyboard
- Mouse
- 6 Month Warranty
- Power Table